2024年6月6日发(作者:休顺美)
Data sheet6ES7155-6MU00-0CN0
SIMATIC ET 200SP, MultiFieldbus, 2-port interface module, IM 155-6MF
High Feature, PN IO, Ethernet IP, Modbus TCP, 1 slot for BusAdapter,
max. 64 I/O modules and 16 ET 200AL modules, multi-hot swap, optional
cable grip, including server module
General information
Product type designation
Firmware version
● FW update possible
Vendor identification (VendorID)
Device identifier (DeviceID)
Manufacturer ID according to ODVA (VendorID)
Device ID according to ODVA (Product code)
Product function
● I&M data
● Module swapping during operation (hot swapping)
● Isochronous mode
● Tool changer
● Local coupling, IO data
● Local coupling, data records
Engineering with
● STEP 7 TIA Portal configurable/integrated from
version
● STEP 7 configurable/integrated from version
● PROFINET from GSD version/GSD revision
● Multi Fieldbus Configuration Tool (MFCT)
Configuration control
via dataset
Supply voltage
Rated value (DC)
permissible range, lower limit (DC)
permissible range, upper limit (DC)
Reverse polarity protection
Mains buffering
● Mains/voltage failure stored energy time
Input current
Current consumption, max.
Inrush current, max.
I²t
Power loss
Power loss, typ.
Address area
Address space per module
● Address space per module, max.288 byte; For input and output data respectively
2.4 W
700 mA
4.5 A
0.25 A²·s
10 ms; according to IEC 61131-2 (6.2.1.3) severity degree PS2
24 V
19.2 V
28.8 V
Yes
Yes
via IM155-6PN/2 HF in compatibility mode
via IM155-6PN/2 HF in compatibility mode
GSDML V2.3
V1.0 Update 2
Yes; I&M0 to I&M3
Yes; Multi-hot swapping
No
Yes; Docking station and docking unit
No
No
IM 155-6 MF HF
V5.1.1
Yes
002AH
0313H
04E3H
0FA2H
6ES71556MU000CN0
Page 1/4
5/16/2022
Subject to change without notice
© Copyright Siemens
Address space per station
● Address space per station, max.
Hardware configuration
Rack
● Quantity of operable ET 200SP modules, max.
● Quantity of operable ET 200AL modules, max.
Submodules
● Number of submodules per station, max.
Time stamping
Accuracy
Interfaces
Number of PROFINET interfaces
1. Interface
Interface types
● Number of ports
● integrated switch
● BusAdapter (PROFINET)
2; via BusAdapter
Yes
Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA
2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA
SCRJ/FC,
Yes
Yes
Yes; PROFINET MRP
1; 2 ports (switch)
10 ms
256
64
16
1 440 byte; Dependent on configuration
Protocols
● PROFINET IO Device
● Open IE communication
● Media redundancy
Interface types
RJ 45 (Ethernet)
● Transmission procedure
● 10 Mbps
● 100 Mbps
● Autonegotiation
● Autocrossing
Protocols
Modbus TCP
Number of connections
● Number of MtM communication
relationships/connections, max.
PROFINET IO Device
Services
— IRT
— PROFIenergy
— Prioritized startup
— Shared device
Redundancy mode
● PROFINET system redundancy (S2)
● H-Sync forwarding
Media redundancy
— MRP
— MRPD
EtherNet/IP
Services
— CIP Implicit Messaging
— CIP Explicit Messaging
— CIP Safety
— Configuration control via Explicit Messaging
— Shared device
Updating times
— Requested Packet Interval (RPI)
Address area
— Address space per module, max.
— ForwardOpen (Class1 & 32 bit Header)
— LargeForwardOpen (Class3)
288 byte; (246 byte outputs / 288 byte inputs)
500 byte; (246 byte outputs / 500 byte inputs)
4 002 byte
2 ms
Yes
Yes
No
No
No
Yes
No
Yes; NAP S2
Yes
No
Yes
No
No
16
Yes
PROFINET with 100 Mbit/s full duplex (100BASE-TX)
No
Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
Yes
Yes
6ES71556MU000CN0
Page 2/4
5/16/2022
Subject to change without notice
© Copyright Siemens
Connections
— Number of rack connections
Modbus TCP
Services
— Read Holding Registers (Code=3)
— Write Multiple Registers (Code=16)
— Parameter change by master
— Modbus TCP Security Protocol
Address space per station
— Address space per station, max.
— Access-consistent address space
Updating time
— I/O request interval
Connections
— Number of connections per slave
Open IE communication
● TCP/IP
● UDP
● SNMP
● LLDP
● ARP
● IGMP
● Multicast
● Broadcast
● IPv4
Interrupts/diagnostics/status information
Status indicator
Alarms
Diagnostics function
Diagnostics indication LED
● RUN LED
● ERROR LED
● MAINT LED
● Monitoring of the supply voltage (PWR-LED)
● NS LED
● MS LED
● IO LED
● Connection display LINK TX/RX
Potential separation
between backplane bus and electronics
between PROFINET and all other circuits
between supply and all other circuits
Isolation
Isolation tested with
Standards, approvals, certificates
Network loading class
Security level
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.
● horizontal installation, max.
● vertical installation, min.
● vertical installation, max.
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
connection method / header
ET-Connection
● via BU/BA Send
Mechanics/material
Yes; + 16 ET 200AL modules
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
-30 °C; No condensation
60 °C
-30 °C; No condensation
50 °C
3
According to Security Level 1 Test Cases V1.1.1
707 V DC (type test)
No
Yes
No
Yes; green LED
Yes; red LED
Yes; Yellow LED
Yes; green PWR LED
Yes; green/red LED
Yes; green/red LED
Yes; red-green-yellow LED
Yes; 2x green link LEDs on BusAdapter
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info)
2 ms
500 byte; (246 byte outputs / 500 byte inputs)
250 byte; (246 byte outputs / 250 byte inputs)
Yes
Yes
Yes
No
1
6ES71556MU000CN0
Page 3/4
5/16/2022
Subject to change without notice
© Copyright Siemens
Strain relief
Dimensions
Width
Height
Depth
Weights
Weight, approx.
last modified:
Yes; Optional
50 mm
117 mm
74 mm
120 g; without BusAdapter
2/10/2022
6ES71556MU000CN0
Page 4/4
5/16/2022
Subject to change without notice
© Copyright Siemens
2024年6月6日发(作者:休顺美)
Data sheet6ES7155-6MU00-0CN0
SIMATIC ET 200SP, MultiFieldbus, 2-port interface module, IM 155-6MF
High Feature, PN IO, Ethernet IP, Modbus TCP, 1 slot for BusAdapter,
max. 64 I/O modules and 16 ET 200AL modules, multi-hot swap, optional
cable grip, including server module
General information
Product type designation
Firmware version
● FW update possible
Vendor identification (VendorID)
Device identifier (DeviceID)
Manufacturer ID according to ODVA (VendorID)
Device ID according to ODVA (Product code)
Product function
● I&M data
● Module swapping during operation (hot swapping)
● Isochronous mode
● Tool changer
● Local coupling, IO data
● Local coupling, data records
Engineering with
● STEP 7 TIA Portal configurable/integrated from
version
● STEP 7 configurable/integrated from version
● PROFINET from GSD version/GSD revision
● Multi Fieldbus Configuration Tool (MFCT)
Configuration control
via dataset
Supply voltage
Rated value (DC)
permissible range, lower limit (DC)
permissible range, upper limit (DC)
Reverse polarity protection
Mains buffering
● Mains/voltage failure stored energy time
Input current
Current consumption, max.
Inrush current, max.
I²t
Power loss
Power loss, typ.
Address area
Address space per module
● Address space per module, max.288 byte; For input and output data respectively
2.4 W
700 mA
4.5 A
0.25 A²·s
10 ms; according to IEC 61131-2 (6.2.1.3) severity degree PS2
24 V
19.2 V
28.8 V
Yes
Yes
via IM155-6PN/2 HF in compatibility mode
via IM155-6PN/2 HF in compatibility mode
GSDML V2.3
V1.0 Update 2
Yes; I&M0 to I&M3
Yes; Multi-hot swapping
No
Yes; Docking station and docking unit
No
No
IM 155-6 MF HF
V5.1.1
Yes
002AH
0313H
04E3H
0FA2H
6ES71556MU000CN0
Page 1/4
5/16/2022
Subject to change without notice
© Copyright Siemens
Address space per station
● Address space per station, max.
Hardware configuration
Rack
● Quantity of operable ET 200SP modules, max.
● Quantity of operable ET 200AL modules, max.
Submodules
● Number of submodules per station, max.
Time stamping
Accuracy
Interfaces
Number of PROFINET interfaces
1. Interface
Interface types
● Number of ports
● integrated switch
● BusAdapter (PROFINET)
2; via BusAdapter
Yes
Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA
2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA
SCRJ/FC,
Yes
Yes
Yes; PROFINET MRP
1; 2 ports (switch)
10 ms
256
64
16
1 440 byte; Dependent on configuration
Protocols
● PROFINET IO Device
● Open IE communication
● Media redundancy
Interface types
RJ 45 (Ethernet)
● Transmission procedure
● 10 Mbps
● 100 Mbps
● Autonegotiation
● Autocrossing
Protocols
Modbus TCP
Number of connections
● Number of MtM communication
relationships/connections, max.
PROFINET IO Device
Services
— IRT
— PROFIenergy
— Prioritized startup
— Shared device
Redundancy mode
● PROFINET system redundancy (S2)
● H-Sync forwarding
Media redundancy
— MRP
— MRPD
EtherNet/IP
Services
— CIP Implicit Messaging
— CIP Explicit Messaging
— CIP Safety
— Configuration control via Explicit Messaging
— Shared device
Updating times
— Requested Packet Interval (RPI)
Address area
— Address space per module, max.
— ForwardOpen (Class1 & 32 bit Header)
— LargeForwardOpen (Class3)
288 byte; (246 byte outputs / 288 byte inputs)
500 byte; (246 byte outputs / 500 byte inputs)
4 002 byte
2 ms
Yes
Yes
No
No
No
Yes
No
Yes; NAP S2
Yes
No
Yes
No
No
16
Yes
PROFINET with 100 Mbit/s full duplex (100BASE-TX)
No
Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
Yes
Yes
6ES71556MU000CN0
Page 2/4
5/16/2022
Subject to change without notice
© Copyright Siemens
Connections
— Number of rack connections
Modbus TCP
Services
— Read Holding Registers (Code=3)
— Write Multiple Registers (Code=16)
— Parameter change by master
— Modbus TCP Security Protocol
Address space per station
— Address space per station, max.
— Access-consistent address space
Updating time
— I/O request interval
Connections
— Number of connections per slave
Open IE communication
● TCP/IP
● UDP
● SNMP
● LLDP
● ARP
● IGMP
● Multicast
● Broadcast
● IPv4
Interrupts/diagnostics/status information
Status indicator
Alarms
Diagnostics function
Diagnostics indication LED
● RUN LED
● ERROR LED
● MAINT LED
● Monitoring of the supply voltage (PWR-LED)
● NS LED
● MS LED
● IO LED
● Connection display LINK TX/RX
Potential separation
between backplane bus and electronics
between PROFINET and all other circuits
between supply and all other circuits
Isolation
Isolation tested with
Standards, approvals, certificates
Network loading class
Security level
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.
● horizontal installation, max.
● vertical installation, min.
● vertical installation, max.
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
connection method / header
ET-Connection
● via BU/BA Send
Mechanics/material
Yes; + 16 ET 200AL modules
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
-30 °C; No condensation
60 °C
-30 °C; No condensation
50 °C
3
According to Security Level 1 Test Cases V1.1.1
707 V DC (type test)
No
Yes
No
Yes; green LED
Yes; red LED
Yes; Yellow LED
Yes; green PWR LED
Yes; green/red LED
Yes; green/red LED
Yes; red-green-yellow LED
Yes; 2x green link LEDs on BusAdapter
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info)
2 ms
500 byte; (246 byte outputs / 500 byte inputs)
250 byte; (246 byte outputs / 250 byte inputs)
Yes
Yes
Yes
No
1
6ES71556MU000CN0
Page 3/4
5/16/2022
Subject to change without notice
© Copyright Siemens
Strain relief
Dimensions
Width
Height
Depth
Weights
Weight, approx.
last modified:
Yes; Optional
50 mm
117 mm
74 mm
120 g; without BusAdapter
2/10/2022
6ES71556MU000CN0
Page 4/4
5/16/2022
Subject to change without notice
© Copyright Siemens