Contains the following system
components:
Operating unit (Model FCM2018-U3
or Model FCM2019-U3)
Fire Terminal Module (Model
FTI20001-U1)
C-WEB Module (Model FN2001-U1)
One-height-unit back box (Models
FHB2001-U1 / R1
One-height-unit outer door
(FHD2001-U3 / R3)
Inner door (Model FHD2005-U1)
Multi-use, main-system interface
modules
Power, Alarm, Supervisory, Silenced,
Ground Fault, Audibles On, and
Trouble system-status LEDs ─ with
Alarm as having a larger, distinctive
LED
Partial system disable LED
Audible Status LEDs (‘On’ and ‘Silenced’)
10 usable LEDs
Model FCM2019-U3 contains one (1)
set of 48 light-emitting diodes(LEDs)
System-control menus
Context-sensitive ‘Help’ menu
Four-way navigation buttons and
extended-views capability
User-prompted large softkey buttons for
multi-programming options and system-
control operating sequence
Seven (7) spare user-programmable
buttons
Slide-in labels appear adjacent to
system-operation buttons
FTI-2001connects to 24VDC power source
via screw terminal
Ribbon cables connect to the
operating unit
Display shows eight [8] lines, 40
characters per row
Plain-text display with two (2) lines of
information per Alarm event
Context-sensitive soft keys
Additional display of location-specific
reaction texts can be stored
Several events are displayed
simultaneously
Model
FHD2001-U3
Operating access for full-system
operation, via password
Several operator terminals are possible
for each fire-detection system [up to 16
nodes, max.]
Optional accessories available:
Auxiliary power supply
RS─485 module (Model FCA2016-U1)
Remote terminal display (Model
FT2014-U3 / R3)
Remote terminal display with control
(Model FT2015-U3 / R3)
Remote peripheral module (Model
FCA2018-U1)
2”─x─ 4-3/4”, back-lit LCD
Style 4 and Style 7 wiring configuration
Requires the C-WEB module (Model
FN2001-U1) for C-NET connection
The Fire Terminal and equipment
connects to C-WEB network that can be
configured for system-global view or
specific-panel local view.
This configuration allows the operator
for system control to ‘acknowledge’
events; control system notification
appliances circuits (NACs), and reset the
system.
The Fire Terminal and equipment allows
for connection to the Remote Peripheral
Module (Model FCA2018-U1) and / or
the Remote Terminal Displays (Models
FT2014-U3 / R3, FT2015-U3 / R3).
The Fire Terminal contains the site-
specific program configuration which is
created in the custom-configuration
programming tool.
Ethernet-port connectivity for system
configuration and Firmware-software
transfers
Compatible with built-in EEPROM
firmware
Can be configured for system global view
and control
Global annunciation and control capability
System operation and indication
Convenient, context and status-sensitive
operation via soft keys
Alphanumeric pad
Model
FCM2018-U3
UL 864 9th Edition Listed, ULC Listed
FM, CSFM and NYC Fire Dept. Approved
Model
FTI2001-U1
Model
FHB2001-U1
Siemens
Smart Infrastructure – Building Products /fire
Data Sheet 9803
The Fire Terminal (Model FT924) consists of the Fire Terminal
Board (Model FTI2001-U1), the Operating Unit (Model
FCM2018-U3 or Model FCM2019-U3), and a one-height-unit
enclosure.
Each Fire Terminal contains one (1) 2” –x– 4-3/4” Video
Graphics Array (VGA) monochrome LCD screen and LEDs for
displaying system status. An audible will sound when there are
unacknowledged events on the system.
The display is surrounded by keys that are used to control the
displayed information, and to navigate through these screens.
Keys are also provided to obtain ‘Help’ and to enter into the
menu features of each operating unit.
The display of each operating unit categorizes events by type,
providing a separate event tab for Alarm, Gas Alarm,
Supervisory, and Trouble events. The quantity of active events
of each type is listed in each event tab. The display provides
two (2) full lines of text message for each event.
Each event can have a 40-character custom message describing
the location for a given event. In addition to the text message,
the system displays the category of the active event: (e.g.
Automatic Alarm, Water Flow, Manual, etc.) the category
means more to responding officials than model numbers.
Up to two (2) events can be displayed at a time. When more
than two (2) events are present, the up-and-down arrow keys
allow the end-user to scroll up and down the list of events. A
progress meter on the side of the list indicates the size of the
list of events and the location in the list. New,
‘unacknowledged’ events are indicated by a flashing
exclamation point ('!').
Each interface also provides a completed menu for running
system status reports (with a ‘Print Preview’ feature directly on
the screen before sending the report to the printer).
The Maintenance menu is accessed by password. When the
end-user enters this mode, the LCD will be enabled, prompting
the user to enter a password. System control within the
maintenance menu uses easy-to-read touch buttons.
The Fire Terminal and equipment are FM (
#
3010), CSFM
(
#
7165-0067:0259) and FDNY (
#
6104) Approved.
Model or
Type
FTI2001-U1
FCM2018-U3
FCM2019-U3
FHB2001-U1
FHB2001-R1
FHB2002-U1
FHB2002-R1
FHD2001-U3
FHD2001-R3
FHD2002-U3
FHD2002-R3
Part
Number
S54400-A58-A1
S54400-C40-A2
S54400-C41-A2
S54400-B47-A1
S54400-B47-A2
S54400-B48-A1
S54400-B48-A2
S54400-B45-A1
S54400-B40-A1
S54400-B32-A1
S54400-C53-A1
Product
Fire Terminal
Operating Unit
Operating Unit (with LED)
One-Height-Unit Back Box,
Black
One-Height-Unit Back Box, Red
Two-Height-Unit Back Box,
Black
Two-Height-Unit Back Box, Red
One-Height-Unit Outer Door,
Black
One-Height-Unit Outer Door,
Red
Two-Height-Unit Outer Door,
Black
Two-Height-Unit Outer Door,
Red
Related Documentation
Product
Fire Terminal Enclosures and
Equipment
Data Sheet
Number
9807
Temperature and Humidity Range
Products are UL 864 9th Edition listed for indoor dry locations
within a temperature range of 120+/ 3°F ( 2°C) to 32+/ 3°F
(0+/ 2°C) and a relative humidity of 93+/ 2% at a temperature
of 90+/ 3°F (32+/ 2°C).
NOTICE –
The information contained in this data-sheet document is intended only
as a summary, and is subject to change without notice.
The product(s) described here has/have a specific instruction sheet(s)
that cover various technical, limitation and liability information.
Copies of install-type, instruction sheets – as well as the General
Product Warning and Limitations document, which also contains
important data, are provided with the product, and are available from
the Manufacturer.
Data contained in the aforesaid type of documentation should be
consulted with a fire-safety professional before specifying or using the
product.
Any further questions or assistance concerning
particular problems that might arise, relative to the
proper functioning of the equipment, please contact
the Manufacturer.
®
PRO
Siemens Industry, Inc.
Smart Infrastructure - Building Products
2 Gatehall Drive • Parsippany, NJ 07054
Tel: (973) 593-2600
March - 2023
(Rev. 4)
2024年10月22日发(作者:集品韵)
Contains the following system
components:
Operating unit (Model FCM2018-U3
or Model FCM2019-U3)
Fire Terminal Module (Model
FTI20001-U1)
C-WEB Module (Model FN2001-U1)
One-height-unit back box (Models
FHB2001-U1 / R1
One-height-unit outer door
(FHD2001-U3 / R3)
Inner door (Model FHD2005-U1)
Multi-use, main-system interface
modules
Power, Alarm, Supervisory, Silenced,
Ground Fault, Audibles On, and
Trouble system-status LEDs ─ with
Alarm as having a larger, distinctive
LED
Partial system disable LED
Audible Status LEDs (‘On’ and ‘Silenced’)
10 usable LEDs
Model FCM2019-U3 contains one (1)
set of 48 light-emitting diodes(LEDs)
System-control menus
Context-sensitive ‘Help’ menu
Four-way navigation buttons and
extended-views capability
User-prompted large softkey buttons for
multi-programming options and system-
control operating sequence
Seven (7) spare user-programmable
buttons
Slide-in labels appear adjacent to
system-operation buttons
FTI-2001connects to 24VDC power source
via screw terminal
Ribbon cables connect to the
operating unit
Display shows eight [8] lines, 40
characters per row
Plain-text display with two (2) lines of
information per Alarm event
Context-sensitive soft keys
Additional display of location-specific
reaction texts can be stored
Several events are displayed
simultaneously
Model
FHD2001-U3
Operating access for full-system
operation, via password
Several operator terminals are possible
for each fire-detection system [up to 16
nodes, max.]
Optional accessories available:
Auxiliary power supply
RS─485 module (Model FCA2016-U1)
Remote terminal display (Model
FT2014-U3 / R3)
Remote terminal display with control
(Model FT2015-U3 / R3)
Remote peripheral module (Model
FCA2018-U1)
2”─x─ 4-3/4”, back-lit LCD
Style 4 and Style 7 wiring configuration
Requires the C-WEB module (Model
FN2001-U1) for C-NET connection
The Fire Terminal and equipment
connects to C-WEB network that can be
configured for system-global view or
specific-panel local view.
This configuration allows the operator
for system control to ‘acknowledge’
events; control system notification
appliances circuits (NACs), and reset the
system.
The Fire Terminal and equipment allows
for connection to the Remote Peripheral
Module (Model FCA2018-U1) and / or
the Remote Terminal Displays (Models
FT2014-U3 / R3, FT2015-U3 / R3).
The Fire Terminal contains the site-
specific program configuration which is
created in the custom-configuration
programming tool.
Ethernet-port connectivity for system
configuration and Firmware-software
transfers
Compatible with built-in EEPROM
firmware
Can be configured for system global view
and control
Global annunciation and control capability
System operation and indication
Convenient, context and status-sensitive
operation via soft keys
Alphanumeric pad
Model
FCM2018-U3
UL 864 9th Edition Listed, ULC Listed
FM, CSFM and NYC Fire Dept. Approved
Model
FTI2001-U1
Model
FHB2001-U1
Siemens
Smart Infrastructure – Building Products /fire
Data Sheet 9803
The Fire Terminal (Model FT924) consists of the Fire Terminal
Board (Model FTI2001-U1), the Operating Unit (Model
FCM2018-U3 or Model FCM2019-U3), and a one-height-unit
enclosure.
Each Fire Terminal contains one (1) 2” –x– 4-3/4” Video
Graphics Array (VGA) monochrome LCD screen and LEDs for
displaying system status. An audible will sound when there are
unacknowledged events on the system.
The display is surrounded by keys that are used to control the
displayed information, and to navigate through these screens.
Keys are also provided to obtain ‘Help’ and to enter into the
menu features of each operating unit.
The display of each operating unit categorizes events by type,
providing a separate event tab for Alarm, Gas Alarm,
Supervisory, and Trouble events. The quantity of active events
of each type is listed in each event tab. The display provides
two (2) full lines of text message for each event.
Each event can have a 40-character custom message describing
the location for a given event. In addition to the text message,
the system displays the category of the active event: (e.g.
Automatic Alarm, Water Flow, Manual, etc.) the category
means more to responding officials than model numbers.
Up to two (2) events can be displayed at a time. When more
than two (2) events are present, the up-and-down arrow keys
allow the end-user to scroll up and down the list of events. A
progress meter on the side of the list indicates the size of the
list of events and the location in the list. New,
‘unacknowledged’ events are indicated by a flashing
exclamation point ('!').
Each interface also provides a completed menu for running
system status reports (with a ‘Print Preview’ feature directly on
the screen before sending the report to the printer).
The Maintenance menu is accessed by password. When the
end-user enters this mode, the LCD will be enabled, prompting
the user to enter a password. System control within the
maintenance menu uses easy-to-read touch buttons.
The Fire Terminal and equipment are FM (
#
3010), CSFM
(
#
7165-0067:0259) and FDNY (
#
6104) Approved.
Model or
Type
FTI2001-U1
FCM2018-U3
FCM2019-U3
FHB2001-U1
FHB2001-R1
FHB2002-U1
FHB2002-R1
FHD2001-U3
FHD2001-R3
FHD2002-U3
FHD2002-R3
Part
Number
S54400-A58-A1
S54400-C40-A2
S54400-C41-A2
S54400-B47-A1
S54400-B47-A2
S54400-B48-A1
S54400-B48-A2
S54400-B45-A1
S54400-B40-A1
S54400-B32-A1
S54400-C53-A1
Product
Fire Terminal
Operating Unit
Operating Unit (with LED)
One-Height-Unit Back Box,
Black
One-Height-Unit Back Box, Red
Two-Height-Unit Back Box,
Black
Two-Height-Unit Back Box, Red
One-Height-Unit Outer Door,
Black
One-Height-Unit Outer Door,
Red
Two-Height-Unit Outer Door,
Black
Two-Height-Unit Outer Door,
Red
Related Documentation
Product
Fire Terminal Enclosures and
Equipment
Data Sheet
Number
9807
Temperature and Humidity Range
Products are UL 864 9th Edition listed for indoor dry locations
within a temperature range of 120+/ 3°F ( 2°C) to 32+/ 3°F
(0+/ 2°C) and a relative humidity of 93+/ 2% at a temperature
of 90+/ 3°F (32+/ 2°C).
NOTICE –
The information contained in this data-sheet document is intended only
as a summary, and is subject to change without notice.
The product(s) described here has/have a specific instruction sheet(s)
that cover various technical, limitation and liability information.
Copies of install-type, instruction sheets – as well as the General
Product Warning and Limitations document, which also contains
important data, are provided with the product, and are available from
the Manufacturer.
Data contained in the aforesaid type of documentation should be
consulted with a fire-safety professional before specifying or using the
product.
Any further questions or assistance concerning
particular problems that might arise, relative to the
proper functioning of the equipment, please contact
the Manufacturer.
®
PRO
Siemens Industry, Inc.
Smart Infrastructure - Building Products
2 Gatehall Drive • Parsippany, NJ 07054
Tel: (973) 593-2600
March - 2023
(Rev. 4)