Data sheet3RW5248-2AC14

SIRIUS soft starter 200-480 V 570 A, 110-250 V AC spring-type

terminals Analog output

Product brand name

Product category

Product designation

Product type designation

Manufacturer's article number

● of HMI module usable

● of HMI-Modul high-feature usable

● of communication module PROFINET standard

usable

● of communication module PROFIBUS usable

● of communication module Modbus TCP usable

● of communication module Modbus RTU usable

● of communication module Ethernet/IP

● of circuit breaker usable at 400 V

● of circuit breaker usable at 500 V

● of circuit breaker usable at 400 V at inside-delta

circuit

● of circuit breaker usable at 500 V at inside-delta

circuit

SIRIUS

Hybrid switching devices

Soft starter

3RW52

3RW5980-0HS00

3RW5980-0HF00

3RW5980-0CS00

3RW5980-0CP00

3RW5980-0CT00

3RW5980-0CR00

3RW5980-0CE00

3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3VA2510-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3VA2510-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3RW5248-2AC14

Page 1/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● of the gG fuse usable up to 690 V

● of the gG fuse usable at inside-delta circuit up

to 500 V

● of full range R fuse link for semiconductor

protection usable up to 690 V

● of back-up R fuse link for semiconductor

protection usable up to 690 V

2x3NA3365-6; Type of coordination 1, Iq = 65 kA

2x3NA3365-6; Type of coordination 1, Iq = 65 kA

3NE1437-2; Type of coordination 2, Iq = 65 kA

3NE3340-8; Type of coordination 2, Iq = 65 kA

General technical data

Starting voltage [%]

Stopping voltage [%]

Start-up ramp time of soft starter

Current limiting value [%] adjustable

Certificate of suitability

● CE marking

● UL approval

● CSA-approval

Product component

● is supported HMI-Standard

● is supported HMI-High Feature

Product feature integrated bypass contact system

Number of controlled phases

Trip class

Buffering time in the event of power failure

● for main current circuit

● for control circuit

Insulation voltage

● rated value

Degree of pollution

Impulse voltage rated value

Blocking voltage of the thyristor maximum

Service factor

Surge voltage resistance rated value

maximum permissible voltage for safe isolation

● between main and auxiliary circuit

Protection class IP

Usage category acc. to IEC 60947-4-2

Shock resistance

Vibration resistance

Reference code acc. to DIN EN 81346-2

Product function

● ramp-up (soft starting)

● ramp-down (soft stop)

● Soft Torque

Yes

Yes

Yes

600 V

IP00

AC 53a

15 g / 11 ms, from 12 g / 11 ms with potential contact lifting

15 mm to 6 Hz; 2g to 500 Hz

Q

600 V

3, acc. to IEC 60947-4-2

6 kV

1 600 V

1

6 kV

100 ms

100 ms

Yes

Yes

Yes

3

CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2

Yes

Yes

Yes

30 ... 100 %

50 ... 50 %

0 ... 20 s

130 ... 700 %

3RW5248-2AC14

Page 2/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● Adjustable current limitation

● pump ramp down

● Intrinsic device protection

● motor overload protection

● Evaluation of thermistor motor protection

● inside-delta circuit

● Auto-reset

● Manual RESET

● remote reset

● communication function

● operating measured value display

● error logbook

● via software parameterizable

● via software configurable

● PROFIenergy

● firmware update

● removable terminal for control circuit

● torque control

● analog output

Yes

Yes

Yes

Yes; Electronic motor overload protection

No

Yes

Yes

Yes

Yes; By turning off the control supply voltage

Yes

Yes; Only in conjunction with special accessories

Yes; Only in conjunction with special accessories

No

Yes

Yes; in connection with the PROFINET Standard communication

module

Yes

Yes

No

Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High

Feature HMI)

Power Electronics

Operating current

● at 40 °C rated value

● at 50 °C rated value

● at 60 °C rated value

Operating current at inside-delta circuit

● at 40 °C rated value

● at 50 °C rated value

● at 60 °C rated value

Operating voltage

● rated value

● at inside-delta circuit rated value

Relative negative tolerance of the operating voltage

Relative positive tolerance of the operating voltage

Relative negative tolerance of the operating voltage

at inside-delta circuit

Relative positive tolerance of the operating voltage at

inside-delta circuit

Operating power for three-phase motors

● at 230 V at 40 °C rated value

160 kW

200 ... 480 V

200 ... 480 V

-15 %

10 %

-15 %

10 %

987 A

873 A

796 A

570 A

504 A

460 A

3RW5248-2AC14

Page 3/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● at 230 V at inside-delta circuit at 40 °C rated

value

● at 400 V at 40 °C rated value

● at 400 V at inside-delta circuit at 40 °C rated

value

Operating frequency 1 rated value

Operating frequency 2 rated value

Relative negative tolerance of the operating

frequency

Relative positive tolerance of the operating frequency

Adjustable motor current

● at rotary encoding switch on switch position 1

● at rotary encoding switch on switch position 2

● at rotary encoding switch on switch position 3

● at rotary encoding switch on switch position 4

● at rotary encoding switch on switch position 5

● at rotary encoding switch on switch position 6

● at rotary encoding switch on switch position 7

● at rotary encoding switch on switch position 8

● at rotary encoding switch on switch position 9

● at rotary encoding switch on switch position 10

● at rotary encoding switch on switch position 11

● at rotary encoding switch on switch position 12

● at rotary encoding switch on switch position 13

● at rotary encoding switch on switch position 14

● at rotary encoding switch on switch position 15

● at rotary encoding switch on switch position 16

● minimum

Adjustable motor current

● for inside-delta circuit at rotary encoding switch

on switch position 1

● for inside-delta circuit at rotary encoding switch

on switch position 2

● for inside-delta circuit at rotary encoding switch

on switch position 3

● for inside-delta circuit at rotary encoding switch

on switch position 4

● for inside-delta circuit at rotary encoding switch

on switch position 5

● for inside-delta circuit at rotary encoding switch

on switch position 6

● for inside-delta circuit at rotary encoding switch

on switch position 7

315 kW

315 kW

560 kW

50 Hz

60 Hz

-10 %

10 %

240 A

262 A

284 A

306 A

328 A

350 A

372 A

394 A

416 A

438 A

460 A

482 A

504 A

526 A

548 A

570 A

240 A

416 A

454 A

492 A

530 A

568 A

606 A

644 A

3RW5248-2AC14

Page 4/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● for inside-delta circuit at rotary encoding switch

on switch position 8

● for inside-delta circuit at rotary encoding switch

on switch position 9

● for inside-delta circuit at rotary encoding switch

on switch position 10

● for inside-delta circuit at rotary encoding switch

on switch position 11

● for inside-delta circuit at rotary encoding switch

on switch position 12

● for inside-delta circuit at rotary encoding switch

on switch position 13

● for inside-delta circuit at rotary encoding switch

on switch position 14

● for inside-delta circuit at rotary encoding switch

on switch position 15

● for inside-delta circuit at rotary encoding switch

on switch position 16

● at inside-delta circuit minimum

Minimum load [%]

Power loss [W] for rated value of the current at AC

● at 40 °C to power-up

● at 50 °C to power-up

● at 60 °C to power-up

Power loss [W] at AC at AC

● at 40 °C during startup

● at 50 °C during startup

● at 60 °C during startup

682 A

721 A

759 A

797 A

835 A

873 A

911 A

949 A

987 A

416 A

15 %; Relative to smallest settable Ie

183 W

163 W

153 W

10 241 W

8 500 W

7 663 W

Control circuit/ Control

Type of voltage of the control supply voltage

Control supply voltage at AC

● at 50 Hz

● at 60 Hz

Relative negative tolerance of the control supply

voltage at AC at 50 Hz

Relative positive tolerance of the control supply

voltage at AC at 50 Hz

Relative negative tolerance of the control supply

voltage at AC at 60 Hz

Relative positive tolerance of the control supply

voltage at AC at 60 Hz

Control supply voltage frequency

Relative negative tolerance of the control supply

voltage frequency

110 ... 250 V

110 ... 250 V

-15 %

10 %

-15 %

10 %

50 ... 60 Hz

-10 %

AC

3RW5248-2AC14

Page 5/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

Relative positive tolerance of the control supply

voltage frequency

Control supply current in standby mode rated value

Holding current in the by-pass mode operating rated

value

Starting current at close of by-pass contact maximum

Inrush current peak at connect of control supply

voltage maximum

Duration of inrush current peak at connect of control

supply voltage

Design of the overvoltage protection

Design of short-circuit protection for control circuit

10 %

30 mA

100 mA

2.2 A

12.2 A

2.2 ms

Varistor

4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1

miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker

(Icu= 300 A); Is not part of scope of supply

Inputs/ Outputs

Number of digital inputs

Number of inputs for thermistor connection

Number of digital outputs

● not parameterizable

Digital output version

Number of analog outputs

Switching capacity current of the relay outputs

● at AC-15 at 250 V rated value

● at DC-13 at 24 V rated value

3 A

1 A

1

0

3

2

2 normally-open contacts (NO) / 1 changeover contact (CO)

1

Installation/ mounting/ dimensions

Mounting position

Mounting type

Height

Width

Depth

Required spacing with side-by-side mounting

● forwards

● Backwards

● upwards

● downwards

● at the side

Installation altitude at height above sea level

maximum

Weight without packaging

10 mm

0 mm

100 mm

75 mm

5 mm

5 000 m; Derating as of 1000 m, see catalog

10.6 kg

with vertical mounting surface +/-90° rotatable, with vertical

mounting surface +/- 22.5° tiltable to the front and back

screw fixing

393 mm

210 mm

203 mm

Connections/ Terminals

Type of electrical connection

● for main current circuit

busbar connection

3RW5248-2AC14

Page 6/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● for control circuit

Width of connection bar maximum

Type of connectable conductor cross-sections

● for DIN cable lug for main contacts stranded

● for DIN cable lug for main contacts finely

stranded

Type of connectable conductor cross-sections

● for control circuit solid

● for control circuit finely stranded with core end

processing

● at AWG conductors for control circuit solid

● at AWG conductors for control circuit finely

stranded with core end processing

Wire length

● between soft starter and motor maximum

● at the digital inputs at AC maximum

Tightening torque

● for main contacts with screw-type terminals

● for auxiliary and control contacts with screw-

type terminals

Tightening torque [lbf·in]

● for main contacts with screw-type terminals

● for auxiliary and control contacts with screw-

type terminals

spring-loaded terminals

45 mm

2x (50 ... 240 mm²)

2x (70 ... 240 mm²)

2x (0.25 ... 1.5 mm²)

2x (0.25 ... 1.5 mm²)

2x (24 ... 16)

2x (24 ... 16)

800 m

100 m

14 ... 24 N·m

0.8 ... 1.2 N·m

124 ... 210 lbf·in

7 ... 10.3 lbf·in

Ambient conditions

Ambient temperature

● during operation

● during storage and transport

Environmental category

● during operation acc. to IEC 60721

● during storage acc. to IEC 60721

● during transport acc. to IEC 60721

EMC emitted interference

3K6 (no ice formation, only occasional condensation), 3C3 (no

salt mist), 3S2 (sand must not get into the devices), 3M6

1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand

must not get inside the devices), 1M4

2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

acc. to IEC 60947-4-2: Class A

-25 ... +60 °C; Please observe derating at temperatures of 40 °C

or above

-40 ... +80 °C

Communication/ Protocol

Communication module is supported

● PROFINET standard

● EtherNet/IP

● Modbus RTU

● Modbus TCP

● PROFIBUS

Yes

Yes

Yes

Yes

Yes

3RW5248-2AC14

Page 7/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

UL/CSA ratings

Manufacturer's article number

● of the fuse

— usable for Standard Faults up to 575/600 V

according to UL

— usable for High Faults up to 575/600 V

according to UL

— usable for Standard Faults at inside-delta

circuit up to 575/600 V according to UL

— usable for High Faults at inside-delta

circuit up to 575/600 V according to UL

Operating power [hp] for three-phase motors

● at 200/208 V at 50 °C rated value

● at 220/230 V at 50 °C rated value

● at 460/480 V at 50 °C rated value

● at 200/208 V at inside-delta circuit at 50 °C

rated value

● at 220/230 V at inside-delta circuit at 50 °C

rated value

● at 460/480 V at inside-delta circuit at 50 °C

rated value

Contact rating of auxiliary contacts according to UL

150 hp

200 hp

400 hp

300 hp

350 hp

750 hp

R300-B300

Type: Class J / L, max. 1600 A; Iq = 30 kA

Type: Class J / L, max. 1200 A; Iq = 100 kA

Type: Class J / L, max. 1600 A; Iq = 30 kA

Type: Class J / L, max. 1200 A; Iq = 100 kA

Safety related data

Electromagnetic compatibilityin accordance with IEC 60947-4-2

Certificates/ approvals

3RW5248-2AC14

Page 8/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

General Product ApprovalEMCDeclaration of

Conformity

Declaration of

Conformity

Miscellaneous

Test Certific-

ates

Type Test Certific-

ates/Test Report

Marine / Shipping

other

Confirmation

Further information

Information- and Downloadcenter (Catalogs, Brochures,…)

/ic10

Industry Mall (Online ordering system)

/mall/en/en/Catalog/product?mlfb=3RW5248-2AC14

Cax online generator

/WW/CAXorder/?lang=en&mlfb=3RW5248-2AC14

Service&Support (Manuals, Certificates, Characteristics, FAQs,...)

/cs/ww/en/ps/3RW5248-2AC14

Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)

/bilddb/cax_?mlfb=3RW5248-2AC14&lang=en

Characteristic: Tripping characteristics, I²t, Let-through current

/cs/ww/en/ps/3RW5248-2AC14/char

Characteristic: Installation altitude

/bilddb/?view=Search&mlfb=3RW5248-2AC14&objecttype=14&gridview=view1

3RW5248-2AC14

Page 9/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

3RW5248-2AC14

Page 10/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

1

4

/

2

4

1

/

L

1

3

/

L

2

5

/

L

3

A

1

-Q

A

2

B

Y

P

A

S

S

E

D

O

N

/

R

U

N

9

5

I

N

2

/

T

1

4

/

T

2

6

/

T

3

1

3

N

O

2

3

N

O

9

8

N

O

9

6

N

C

A

Q

I

+

3RW5248-2AC14

Page 11/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

A

Q

U

+

A

Q

-

last modified:

05/04/2020

3RW5248-2AC14

Page 12/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

2024年10月24日发(作者:第五飞文)

Data sheet3RW5248-2AC14

SIRIUS soft starter 200-480 V 570 A, 110-250 V AC spring-type

terminals Analog output

Product brand name

Product category

Product designation

Product type designation

Manufacturer's article number

● of HMI module usable

● of HMI-Modul high-feature usable

● of communication module PROFINET standard

usable

● of communication module PROFIBUS usable

● of communication module Modbus TCP usable

● of communication module Modbus RTU usable

● of communication module Ethernet/IP

● of circuit breaker usable at 400 V

● of circuit breaker usable at 500 V

● of circuit breaker usable at 400 V at inside-delta

circuit

● of circuit breaker usable at 500 V at inside-delta

circuit

SIRIUS

Hybrid switching devices

Soft starter

3RW52

3RW5980-0HS00

3RW5980-0HF00

3RW5980-0CS00

3RW5980-0CP00

3RW5980-0CT00

3RW5980-0CR00

3RW5980-0CE00

3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3VA2510-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3VA2510-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10

3RW5248-2AC14

Page 1/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● of the gG fuse usable up to 690 V

● of the gG fuse usable at inside-delta circuit up

to 500 V

● of full range R fuse link for semiconductor

protection usable up to 690 V

● of back-up R fuse link for semiconductor

protection usable up to 690 V

2x3NA3365-6; Type of coordination 1, Iq = 65 kA

2x3NA3365-6; Type of coordination 1, Iq = 65 kA

3NE1437-2; Type of coordination 2, Iq = 65 kA

3NE3340-8; Type of coordination 2, Iq = 65 kA

General technical data

Starting voltage [%]

Stopping voltage [%]

Start-up ramp time of soft starter

Current limiting value [%] adjustable

Certificate of suitability

● CE marking

● UL approval

● CSA-approval

Product component

● is supported HMI-Standard

● is supported HMI-High Feature

Product feature integrated bypass contact system

Number of controlled phases

Trip class

Buffering time in the event of power failure

● for main current circuit

● for control circuit

Insulation voltage

● rated value

Degree of pollution

Impulse voltage rated value

Blocking voltage of the thyristor maximum

Service factor

Surge voltage resistance rated value

maximum permissible voltage for safe isolation

● between main and auxiliary circuit

Protection class IP

Usage category acc. to IEC 60947-4-2

Shock resistance

Vibration resistance

Reference code acc. to DIN EN 81346-2

Product function

● ramp-up (soft starting)

● ramp-down (soft stop)

● Soft Torque

Yes

Yes

Yes

600 V

IP00

AC 53a

15 g / 11 ms, from 12 g / 11 ms with potential contact lifting

15 mm to 6 Hz; 2g to 500 Hz

Q

600 V

3, acc. to IEC 60947-4-2

6 kV

1 600 V

1

6 kV

100 ms

100 ms

Yes

Yes

Yes

3

CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2

Yes

Yes

Yes

30 ... 100 %

50 ... 50 %

0 ... 20 s

130 ... 700 %

3RW5248-2AC14

Page 2/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● Adjustable current limitation

● pump ramp down

● Intrinsic device protection

● motor overload protection

● Evaluation of thermistor motor protection

● inside-delta circuit

● Auto-reset

● Manual RESET

● remote reset

● communication function

● operating measured value display

● error logbook

● via software parameterizable

● via software configurable

● PROFIenergy

● firmware update

● removable terminal for control circuit

● torque control

● analog output

Yes

Yes

Yes

Yes; Electronic motor overload protection

No

Yes

Yes

Yes

Yes; By turning off the control supply voltage

Yes

Yes; Only in conjunction with special accessories

Yes; Only in conjunction with special accessories

No

Yes

Yes; in connection with the PROFINET Standard communication

module

Yes

Yes

No

Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High

Feature HMI)

Power Electronics

Operating current

● at 40 °C rated value

● at 50 °C rated value

● at 60 °C rated value

Operating current at inside-delta circuit

● at 40 °C rated value

● at 50 °C rated value

● at 60 °C rated value

Operating voltage

● rated value

● at inside-delta circuit rated value

Relative negative tolerance of the operating voltage

Relative positive tolerance of the operating voltage

Relative negative tolerance of the operating voltage

at inside-delta circuit

Relative positive tolerance of the operating voltage at

inside-delta circuit

Operating power for three-phase motors

● at 230 V at 40 °C rated value

160 kW

200 ... 480 V

200 ... 480 V

-15 %

10 %

-15 %

10 %

987 A

873 A

796 A

570 A

504 A

460 A

3RW5248-2AC14

Page 3/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● at 230 V at inside-delta circuit at 40 °C rated

value

● at 400 V at 40 °C rated value

● at 400 V at inside-delta circuit at 40 °C rated

value

Operating frequency 1 rated value

Operating frequency 2 rated value

Relative negative tolerance of the operating

frequency

Relative positive tolerance of the operating frequency

Adjustable motor current

● at rotary encoding switch on switch position 1

● at rotary encoding switch on switch position 2

● at rotary encoding switch on switch position 3

● at rotary encoding switch on switch position 4

● at rotary encoding switch on switch position 5

● at rotary encoding switch on switch position 6

● at rotary encoding switch on switch position 7

● at rotary encoding switch on switch position 8

● at rotary encoding switch on switch position 9

● at rotary encoding switch on switch position 10

● at rotary encoding switch on switch position 11

● at rotary encoding switch on switch position 12

● at rotary encoding switch on switch position 13

● at rotary encoding switch on switch position 14

● at rotary encoding switch on switch position 15

● at rotary encoding switch on switch position 16

● minimum

Adjustable motor current

● for inside-delta circuit at rotary encoding switch

on switch position 1

● for inside-delta circuit at rotary encoding switch

on switch position 2

● for inside-delta circuit at rotary encoding switch

on switch position 3

● for inside-delta circuit at rotary encoding switch

on switch position 4

● for inside-delta circuit at rotary encoding switch

on switch position 5

● for inside-delta circuit at rotary encoding switch

on switch position 6

● for inside-delta circuit at rotary encoding switch

on switch position 7

315 kW

315 kW

560 kW

50 Hz

60 Hz

-10 %

10 %

240 A

262 A

284 A

306 A

328 A

350 A

372 A

394 A

416 A

438 A

460 A

482 A

504 A

526 A

548 A

570 A

240 A

416 A

454 A

492 A

530 A

568 A

606 A

644 A

3RW5248-2AC14

Page 4/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● for inside-delta circuit at rotary encoding switch

on switch position 8

● for inside-delta circuit at rotary encoding switch

on switch position 9

● for inside-delta circuit at rotary encoding switch

on switch position 10

● for inside-delta circuit at rotary encoding switch

on switch position 11

● for inside-delta circuit at rotary encoding switch

on switch position 12

● for inside-delta circuit at rotary encoding switch

on switch position 13

● for inside-delta circuit at rotary encoding switch

on switch position 14

● for inside-delta circuit at rotary encoding switch

on switch position 15

● for inside-delta circuit at rotary encoding switch

on switch position 16

● at inside-delta circuit minimum

Minimum load [%]

Power loss [W] for rated value of the current at AC

● at 40 °C to power-up

● at 50 °C to power-up

● at 60 °C to power-up

Power loss [W] at AC at AC

● at 40 °C during startup

● at 50 °C during startup

● at 60 °C during startup

682 A

721 A

759 A

797 A

835 A

873 A

911 A

949 A

987 A

416 A

15 %; Relative to smallest settable Ie

183 W

163 W

153 W

10 241 W

8 500 W

7 663 W

Control circuit/ Control

Type of voltage of the control supply voltage

Control supply voltage at AC

● at 50 Hz

● at 60 Hz

Relative negative tolerance of the control supply

voltage at AC at 50 Hz

Relative positive tolerance of the control supply

voltage at AC at 50 Hz

Relative negative tolerance of the control supply

voltage at AC at 60 Hz

Relative positive tolerance of the control supply

voltage at AC at 60 Hz

Control supply voltage frequency

Relative negative tolerance of the control supply

voltage frequency

110 ... 250 V

110 ... 250 V

-15 %

10 %

-15 %

10 %

50 ... 60 Hz

-10 %

AC

3RW5248-2AC14

Page 5/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

Relative positive tolerance of the control supply

voltage frequency

Control supply current in standby mode rated value

Holding current in the by-pass mode operating rated

value

Starting current at close of by-pass contact maximum

Inrush current peak at connect of control supply

voltage maximum

Duration of inrush current peak at connect of control

supply voltage

Design of the overvoltage protection

Design of short-circuit protection for control circuit

10 %

30 mA

100 mA

2.2 A

12.2 A

2.2 ms

Varistor

4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1

miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker

(Icu= 300 A); Is not part of scope of supply

Inputs/ Outputs

Number of digital inputs

Number of inputs for thermistor connection

Number of digital outputs

● not parameterizable

Digital output version

Number of analog outputs

Switching capacity current of the relay outputs

● at AC-15 at 250 V rated value

● at DC-13 at 24 V rated value

3 A

1 A

1

0

3

2

2 normally-open contacts (NO) / 1 changeover contact (CO)

1

Installation/ mounting/ dimensions

Mounting position

Mounting type

Height

Width

Depth

Required spacing with side-by-side mounting

● forwards

● Backwards

● upwards

● downwards

● at the side

Installation altitude at height above sea level

maximum

Weight without packaging

10 mm

0 mm

100 mm

75 mm

5 mm

5 000 m; Derating as of 1000 m, see catalog

10.6 kg

with vertical mounting surface +/-90° rotatable, with vertical

mounting surface +/- 22.5° tiltable to the front and back

screw fixing

393 mm

210 mm

203 mm

Connections/ Terminals

Type of electrical connection

● for main current circuit

busbar connection

3RW5248-2AC14

Page 6/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

● for control circuit

Width of connection bar maximum

Type of connectable conductor cross-sections

● for DIN cable lug for main contacts stranded

● for DIN cable lug for main contacts finely

stranded

Type of connectable conductor cross-sections

● for control circuit solid

● for control circuit finely stranded with core end

processing

● at AWG conductors for control circuit solid

● at AWG conductors for control circuit finely

stranded with core end processing

Wire length

● between soft starter and motor maximum

● at the digital inputs at AC maximum

Tightening torque

● for main contacts with screw-type terminals

● for auxiliary and control contacts with screw-

type terminals

Tightening torque [lbf·in]

● for main contacts with screw-type terminals

● for auxiliary and control contacts with screw-

type terminals

spring-loaded terminals

45 mm

2x (50 ... 240 mm²)

2x (70 ... 240 mm²)

2x (0.25 ... 1.5 mm²)

2x (0.25 ... 1.5 mm²)

2x (24 ... 16)

2x (24 ... 16)

800 m

100 m

14 ... 24 N·m

0.8 ... 1.2 N·m

124 ... 210 lbf·in

7 ... 10.3 lbf·in

Ambient conditions

Ambient temperature

● during operation

● during storage and transport

Environmental category

● during operation acc. to IEC 60721

● during storage acc. to IEC 60721

● during transport acc. to IEC 60721

EMC emitted interference

3K6 (no ice formation, only occasional condensation), 3C3 (no

salt mist), 3S2 (sand must not get into the devices), 3M6

1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand

must not get inside the devices), 1M4

2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

acc. to IEC 60947-4-2: Class A

-25 ... +60 °C; Please observe derating at temperatures of 40 °C

or above

-40 ... +80 °C

Communication/ Protocol

Communication module is supported

● PROFINET standard

● EtherNet/IP

● Modbus RTU

● Modbus TCP

● PROFIBUS

Yes

Yes

Yes

Yes

Yes

3RW5248-2AC14

Page 7/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

UL/CSA ratings

Manufacturer's article number

● of the fuse

— usable for Standard Faults up to 575/600 V

according to UL

— usable for High Faults up to 575/600 V

according to UL

— usable for Standard Faults at inside-delta

circuit up to 575/600 V according to UL

— usable for High Faults at inside-delta

circuit up to 575/600 V according to UL

Operating power [hp] for three-phase motors

● at 200/208 V at 50 °C rated value

● at 220/230 V at 50 °C rated value

● at 460/480 V at 50 °C rated value

● at 200/208 V at inside-delta circuit at 50 °C

rated value

● at 220/230 V at inside-delta circuit at 50 °C

rated value

● at 460/480 V at inside-delta circuit at 50 °C

rated value

Contact rating of auxiliary contacts according to UL

150 hp

200 hp

400 hp

300 hp

350 hp

750 hp

R300-B300

Type: Class J / L, max. 1600 A; Iq = 30 kA

Type: Class J / L, max. 1200 A; Iq = 100 kA

Type: Class J / L, max. 1600 A; Iq = 30 kA

Type: Class J / L, max. 1200 A; Iq = 100 kA

Safety related data

Electromagnetic compatibilityin accordance with IEC 60947-4-2

Certificates/ approvals

3RW5248-2AC14

Page 8/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

General Product ApprovalEMCDeclaration of

Conformity

Declaration of

Conformity

Miscellaneous

Test Certific-

ates

Type Test Certific-

ates/Test Report

Marine / Shipping

other

Confirmation

Further information

Information- and Downloadcenter (Catalogs, Brochures,…)

/ic10

Industry Mall (Online ordering system)

/mall/en/en/Catalog/product?mlfb=3RW5248-2AC14

Cax online generator

/WW/CAXorder/?lang=en&mlfb=3RW5248-2AC14

Service&Support (Manuals, Certificates, Characteristics, FAQs,...)

/cs/ww/en/ps/3RW5248-2AC14

Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)

/bilddb/cax_?mlfb=3RW5248-2AC14&lang=en

Characteristic: Tripping characteristics, I²t, Let-through current

/cs/ww/en/ps/3RW5248-2AC14/char

Characteristic: Installation altitude

/bilddb/?view=Search&mlfb=3RW5248-2AC14&objecttype=14&gridview=view1

3RW5248-2AC14

Page 9/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

3RW5248-2AC14

Page 10/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

1

4

/

2

4

1

/

L

1

3

/

L

2

5

/

L

3

A

1

-Q

A

2

B

Y

P

A

S

S

E

D

O

N

/

R

U

N

9

5

I

N

2

/

T

1

4

/

T

2

6

/

T

3

1

3

N

O

2

3

N

O

9

8

N

O

9

6

N

C

A

Q

I

+

3RW5248-2AC14

Page 11/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

A

Q

U

+

A

Q

-

last modified:

05/04/2020

3RW5248-2AC14

Page 12/

12

05/06/2020

Subject to change without notice

© Copyright Siemens

发布评论

评论列表 (0)

  1. 暂无评论